1Department of Basic Science U.P. Textile Institute Kanpur UP India
2Department of Physics T.D. College Jaunpur U.P India
3Department of Applied Science and Humanities, Buddha Institute of TechnologyCl-1Gida Gorakpur U.P.India
Email:- dev07.2007@rediffmail.com
In the present paper a new method has been developed to evaluate decay parameters and order of kinetics by analyzing thermoluminescence (TL) glow curve. It has been observed that the decay parameters are characteristic feature of the system under investigation whereas order of kinetics does not. Extents of recombination and simultaneous retrapping decides the order of kinetics involved in the T L process. Order of kinetics increases with extent of retrapping within the system. TL decay parameters, order of kinetics and initial concentration of trapped electrons per unit volume are evaluated easily and conveniently following the proposed method of analysis.
Copy the following to cite this article:
DEVENDRA PRASAD1, A. N. THAKUR2, and JAI PRAKASH3, "T L Glow Curve Analysis Technique for Evaluation of Decay Parameters and Order of Kinetics", Journal of Ultra Scientist of Physical Sciences, Volume 24, Issue 3, Page Number , 2016Copy the following to cite this URL:
DEVENDRA PRASAD1, A. N. THAKUR2, and JAI PRAKASH3, "T L Glow Curve Analysis Technique for Evaluation of Decay Parameters and Order of Kinetics", Journal of Ultra Scientist of Physical Sciences, Volume 24, Issue 3, Page Number , 2016Available from: http://ultraphysicalsciences.org/paper/525/